X6200 Firmware, Manuals & Utils
X6200_Update_1.0.7 (251012) — Release Notes [EN]
- Optimized the AGC algorithm and fine-tuned the AGC rise time in each mode to improve the listening experience.
- Fixed a bug where WFM demodulation would become silent after being left idle for a period of time.
- Fixed a bug where battery capacity detection was inaccurate.
- Fixed a bug that caused crackling noise in the received audio after the CW decoder was turned on.
- Optimized the NR algorithm.
- Changed the baseband uplink data to use SLIP encoding.
- Added 2.5 kHz and 5 kHz tuning step options in SSB mode.
- Changed the preset filter bandwidths in AM mode to 9 / 12 / 15 kHz.
- Optimized the receiving noise floor.
- Added an option to display the receiving level in the upper-left corner of the spectrum window
(DISPLAY 3/3 > SHOW RX LEVEL, default =OFF) - Added two waterfall chart speed options: NORMAL / SLOW
(DISPLAY 3/3 > WATERFALL SPEED, default = NORMAL). - Modified the upper frequency limit to 136 MHz (consistent with the manual).
- Fixed a bug that caused a black screen and disconnection when rotating the main tuning wheel quickly while connected to a WR12.
- Fixed a bug that caused the spectrum display to freeze (in severe cases, the entire screen would freeze) when the RF spectrum line color transparency was set below 255.
- Removed the CW option from the MODEM interface (the CW decoder has been moved to the KEY menu).
- Added a 3D BANDSCOPE option
(DISPLAY 3/3 > 3D BANDSCOPE = ON).
Full article outlining the improvements ➜
© Pileup Communications 2025
Xiegu X6200 firmware update with new features, optimisations and a few bug fixes.
IMPROVEMENTS
- Added new CW decoder on the second page of the KEY menu. Press the [CW Decoder] button to turn it ON/OFF. When CW Decoder is ON decoded text will scroll from right to left and be displayed at the bottom of the waterfall diagram. Press the “CW Decoding Threshold” and use the outer ring of the MFK to adjust it between 1 to 50. Adjust it to optimize decoding rate. For lower noise levels try a setting between 5 – 14, for higher noise levels (S9) use 15-30.
- Added full support for FT8CN via Bluetooth
- Added support for the new Xiegu WR12 Wide-Band receiver Add-on module. A blue WR12 icon will appear in the upper right corner left to the voltage display whenever the WR12 Add-on is connected to the Xiegu X6200 HOST port.
- Optimized the NR algorithm.
- Added NETWORK information in the SYSTEN INFO Menu
FIXES
- AM Modulation fixed
- Deviation level for NFM adjusted
- Improved battery gauge accuracy
- Changed VFO frequency color to darker green to avoid glare at night.
Xiegu X6200 firmware update with new features, optimisations and a few bug fixes. For a full list of improvements, see the read-me-1st.txt file in the archive.
X6100 Firmware, Manuals & Utils
NOTICE: The v1.1.8-240904002 update was withdrawn on request by Xiegu. If you have updated your X6100 and experience TX failure issues, this update will resolve the issue.
v1.1.9 240915001 Release Note
Image File SHA256: a627dd9a2e18ef92a8df1ec03d51c430f03f92eb19b40fc0935dc2d188578c88
APP: V1.1.9 Sep 14 2024,12:11:57
BASE: V1.1.8 Sep 15 2024,15:22:37
1) Fixed TX problem with specific hardware after updating to v1.1.8.
2) Color scheme updated for better visibility in sunlight.
v1.1.8 240904002 Release Notes
Image File SHA256: 31d0bffe9817efbb2ce94db910c5cf2d1e72617976cd2326526298e22dfc04b2
APP: V1.1.8 Sep 4 2024,14:11:48
BASE: V1.1.7 Sep 4 2024,11:35:33
- The gain allocation in the baseband section adjusted to improve the received signal to noise ratio, to reduce broadcast crosstalk, and o minimize birdies.
- Adjusted the spectrum/waterfall automatic level tracking mode to improve the signal contrast when dealing with strong signals, easier to distinguish between signal and noise.
- Added audio spectrum/oscilloscope switch, when turned off the spectrum/waterfall will be use the full svreen.
- Fixed a bug where MFK tags could not be saved.
- Optimized the NR, noise Reduction algorithm.
- Adjusted the CI-V data format.
- Adjusted the operation logic of the WLAN settings interface.
- Adjusted the operation logic of BLUETOOTH setting interface.
CIV commands reference for Xiegu transceivers.
V1.1.7 Release Note
Image File SHA256: BF153B10AB3D942060E65BE35A64A2D6C419A5EFF8D941E5C8CE93CE6DD44305
APP: V1.1.7 Jul 26 2023,11:50:55
BASE: V1.1.6 Mar 7 2023,09:57:03
NOTICE: Consider this version experimental! For normal use we recommend version 1.1.6.
1. Added wfview server to enable support for wfview, see included ‘x6100 wfserver.pdf’ file for setup instructions.
wfview is a free and open source program that allows many modern Icom ham radio transceivers (such as the Xiegu X6100, IC-7300, IC-9700, IC-7610, IC-R8600, the IC-705, and many others) to be controlled via a computer. wfview shows the gorgeous spectrum display on whatever display is connected, including projectors, touch screens, and TVs. wfview allows for full radio (remote) control from a computer keyboard and basic control from a numeric keypad. wfview can run on hardware ranging from the $35 Raspberry Pi to laptops to desktops. wfview runs on recent versions of Linux, macOS, and Windows. wfview supports rig control over ethernet/wifi as well as over the traditional USB serial CIV bus. wfview also allows older radios to be accessed over the internet, for full control and low-latency audio streaming.
More information about wfview is found at wfview.org.
Tips & Note:
#### The X6100 internal WiFi antenna is only usable when adjacent to the access point. Consistent performance is achieved by connecting a wired USB-C LAN dongle to the HOST connector using a LAN cable between the radio and access point.
Always read the enclosed update log!
ATTENTION: If you have firmware older than the previous January 17 update, please see the below information regarding the battery management update;
1. The built-in battery gauge is enabled to manage the battery cell. After the upgrade, the battery voltage will no longer be used as the management data, but the battery capacity measured by the battery gauge will be used as the management data. The relevant precautions are as follows:
1.1 After updating the firmware, please perform 4 full charge and full discharge cycles in a row, after which the fuel gauge will measure accurately. Just after updating the firmware, before the 4 times of charge and discharge are completed, the displayed power error is large, so don’t pay attention to it. The charging process should be kept as continuous as possible until the charging instruction is completed, which is conducive to the accurate capacity determination of the fuel gauge.
1.2 The updated charging indicator status is as follows:
Blinking: Indicates charging
Steady on: Indicates that charging is complete
Off: When the charging option is turned off in the menu, the indicator light will not be on.
1.3 After the update, when the power is lower than 10%, the battery symbol shows red and the interior is empty, and the device will automatically shut down.
1.4 The battery voltage is no longer used as the basis for the judgment of low battery.
Tool to create SD card with FW updates for Xiegu X6100. Download Firmware Update Tutorial for instructions.
The purpose of this tutorial is to guide operators to connect the X6100 to a PC for operating FT8 and other digital modes.
G90 Firmware, Manuals & Utils
This is the v1.81 Firmware for Xiegu G90 with both Main Unit and Display unit firmware files.
Fixes & Improvements
Head Unit Changes:
- Fixed a bug where a small black box appeared in the upper-right corner of the TX ERROR prompt page.
- Fixed a bug where automatic antenna tuning would get stuck in SLPT mode.
Main Unit Changes:
- Fixed a bug where NFM had no receive (RX) audio.
- Adjusted the display method of the ALC value:
– Range: 0-100
– Meaning: Indicates MIC or LINE IN audio level. A higher value represents a stronger input signal.
When operating in DIGI mode, adjust the LINE IN gain or PC volume to ensure the ALC value remains
≤ 50 for optimal linearity.
CIV commands reference for Xiegu transceivers.
This cheat sheet is intended to augment the current G90 user manual (and there are several versions) and reflects the G90’s functionality of its firmware. Use the first column to look up the various G90 controls or buttons. Use the second column to look up the G90 supported functions (i.e. RF Gain, VOX, etc.). Also, see the release notes at the very end to get an idea when various features first appeared in the G90 firmware.
Published with permission of author, KE8WO. Thanks Gary!
Connections and settings for data communications and digital modes using the XIEGU G90 or X5105 transceivers.
Xiegu G90 review from QST March 2020. Published with permission of ARRL.
The latest operation manual for the Xiegu G90 20 watt HF SDR transceiver.
G106 Firmware, Manuals & Utils
Xiegu G106 Firmware Update 1.4 build 01 (June 18, 2025).
1. Improved AGC algorithm
2. Improved I/Q balance algoritm
3. Added CI-V command to switch between built-in/external speakers:
– 1D 02 01 [XX]
– XX=0: Built-in speaker
– XX!=0: External speaker(MIC handle speaker)
NOTICE: If you have a TX frequency extension applied to your G106 you will loose the extension when updating to v1.4. If you like to retain the extension please create a support ticket and refer to your order number for further information.
This document by Gabor HA3MGA contain information on how to download and use his clever RigCAT XML control file created for Xiegu G106. The document also contain a link to the official Fldigi download of the needed XML file.
CIV commands reference for Xiegu transceivers.
Xiegu G106 Firmware Update 1.3 build 03 (May 9, 2023).
G106 Firmware Upgrade Guide
The latest operation manual for the Xiegu G106 QRP transceiver.
X5105 Firmware, Manuals & Utils
CIV commands reference for Xiegu transceivers.
Instruction Manual for Xiegu X5105 HF and 6m QRP transceiver.
Connections and settings for data communications and digital modes using the XIEGU G90 or X5105 transceivers.
This is a smaller upgrade of the firmware with some bug fixes. Before uploading the firmware to your X5105, please read the update tutorial!
G1M Firmware, Manuals & Utils
The lastest operation manual for the Xiegu G1M QRP transceiver.
GSOC Firmware, Manuals & Utils
XPA125B Firmware, Manuals & Utils
User manual for the Xiegu XPA125B 100 watt HF+6 meter amplifier.
Xiegu Accessories
This the operation manual for the DE-19 Digital Modes USB adapter compatible with Xiegu G90, G106 and X5105.
Instructions for how to use the CN-20 adapter to connect the XPA125B to a Yaesu FT-817 or FT-818 transceiver.
This document has all the relevant information on how to connect the CE19 data expansion port with your Xiegu transceiver and a PC for digital modes. It also have information about how to connect an external amplifier.